NMR spectrometers at MLU are operated in three locations. The locations are assigned to the participating research institutes, but are within walking distance of each other. At the Institute of Physics, two research groups work with their respective devices in the same building, which was specially built for the NMR spectrometers, but are listed separately.
The following is a list of the different locations with their equipment and measurement methods.
Location NF2C at the Institute of Chemistry
Spectrometers
500MHz
Console:
• Agilent DD2
Probe:
• 5 mm PFG OneNMR 1H(19F), 15N-31P, Z-Grad.
400MHz
Console:
• Agilent VNMRS
Probe:
• 5 mm PFG OneNMR 1H(19F), 15N-31P, Z-Grad.
2 x Benchtop 80MHz
Consoles:
• Magritek Spinsolve
• Bruker Fourier80
Probes:
• 5 mm; 1H, 13C, 19F; autosampler, flow cell
• 5 mm; 1 H, 31P
Methods
-
- All common high-resolution 1H- and X-nucleus 1D and 2D characterisation methods, e.g. DEPT/APT, COSY, NOESY, HSQC/HETCOR…
Location NF1BC at the Institute of Biochemistry
Spectrometers
700MHz
Console:
• Bruker Avance III
Probes:
• 5 mm TXI 1H, 13C, 15N, Z-Grad.;
• 5 mm BBI 1H, 31P-207Pb, Z-Grad.;
• 4 mm HR-MAS DVT 1H,13C,15N, 2H, Z-Grad., 6 kHz
400MHz
Console:
• Bruker Avance III
Probes:
• 5 mm TBI 1H, 13C, 31P – 15N Z-Grad.;
• 5 mm BBFO 1H(19F), 31P-109Ag, Z-Grad.;
• 4 mm HR-MAS 1H, 13C, 15N, 2H Z-Grad. 6 kHz;
• 4 mm HR-MAS 1H, 31P, 13C, 2H Z-Grad. 6 kHz
Benchtop 60MHz
Console:
• Magritek Spinsolve
Probe:
• 1H, 19F, 13C
Methods
-
- All common high-resolution 1H/19F- and X-nucleus (X = 13C, 15N, 31P, 33S, 67Zn…) 1D and 2D characterisation methods, e.g. DEPT/APT, COSY, NOESY, ROESY, TOCSY, HSQC, HMBC, DOSY, etc.
- HR-MAS rotor systems 4 mm (up to 6 kHz) with 2H-lock and 1H/13C/15N or 1H/31P/13C channels for the investigation of highly viscous samples
- 13C, 15N relaxometry (T1, T1ρ, T2, HetNOE) for the investigation of molecular dynamics
Due to the limited sample throughput resulting from the mixed operation, the service offer concentrates on more elaborate measurement series on selected samples.
Location NF2P at the Institute of Physics – NMR
Spectrometers
3 x 400MHz (wide bore)
Consoles:
• Bruker Avance III
• Bruker Avance II/III
Probes:
• 4 mm MAS DVT BB HXY
• 4 mm MAS WVT BB HX
• 3.2 mm MAS DVT BB HX
• 5 mm static VTN BB HX with goniometer option
• 5 mm Diff60/Micro5, 1H, X (inserts: 2H, 13C, 15N, 7Li, 19F)
200MHz (wide bore)
Console:
• Bruker Avance III
Probe:
• 5 mm static VTN 1H
3 x Minispec 20MHz
Console:
• Bruker Minispec mq20
Probes:
• 1H low field relaxometry
• 1 device with pulsed field gradient diffusometry
Methods
-
- 1H/19F- and 1H-X (X=13C, 15N, 31P, 2H, 29Si, 6/7Li, 11B, …) CP or DP MAS NMR, 1D, 2D HETCOR/WISE, DQ, etc.,
- MAS rotor systems 4 mm (up to 15 kHz), 3.2 mm (up to 24 kHz), 2.5 mm (up to 35 kHz) and 1.3 mm (up to 70 kHz, especially for 1H high-resolution in solids), 3.2 mm MAS E-free system (600 MHz) for aqueous/conductive samples
- Static broad line spectroscopy (1H, 2H, 13C, 31P, …) for dynamic measurements
- 1H-13C order parameter measurements (DIPSHIFT/PDLF), especially for membrane lipids and liquid crystals
- 1H and X-nucleus relaxometry (T1, T1ρ, T2), high resolution (MAS) or in the time domain, for characterisation of molecular dynamics, dynamic heterogeneities and multiphase structure
- Static 1H multiquantum NMR (especially low-field/benchtop) to study chain dynamics and crosslinking structure in polymer melts, elastomers and gels
- Static and MAS (CODEX) exchange NMR for slow dynamics
- Pulsed field gradient diffusometry (up to 30 T/m) for slow diffusion in soft matter up to D ~ 5 x 10-15 m2/s
- Biomolecular solid-state NMR, especially high-resolution 15N- and 1H-based relaxometry for protein dynamics
Location NF2P at the Institute of Physics – Biophysics
Spectrometers
800MHz
Console:
• Bruker Avance III
Probes:
• 5 mm TXO Cryo 13C observe, 1H, 15N, Z-Grad.
• 5 mm TCI Cryo 1H, 13C, 15N, Z-Grad.
• 5 mm QXI 1H, 31P, 13C, 15N, Z-Grad.
2 x 600MHz
Consoles:
• Bruker Avance III
•Bruker Avance II+
Probes:
• 5mm TXI 1H, 13C, 15N, Z-Grad.
• 3 mm TBI 1H, 13C, 31P – 15N, Z-Grad.
• 5 mm QXI 1H, 31P, 13C, 15N, Z-Grad.
• 8 mm mixing chamber probe 1H, 13C, Z-Grad.
• 5 mm TXI 1H, 13C, 15N, Z-Grad.
• 5mm BBI 1H, 31P-109Ag, Z-Grad.
• 4 mm MAS DVT 1H, 13C, 15N, 15 kHz
• 2.5 mm MAS VTN 1H, 15N-31P, 35 kHz high pressure setup up to 2500 bar
500MHz
Console:
• Bruker AMX/DRX
Probe:
• 5 mm TXI 1H, 13C, 15N Z-Grad.
Methods
-
- Multi-dimensional multiresonance experiments on isotope-marked proteins (15N, 13C, 2H)
- Time-resolved protein NMR
- Relaxation dispersion
- High pressure NMR up to 2500bar